- Contact Person : Mr. he Alan
- Company Name : Shenzhen Hua-Real Semiconductor Lighting Co., Ltd.
- Tel : 86-755-28193310
- Fax : 86-755-28193573
- Address : Guangdong,Shenzhen,209,2F,No1 Building,Zhonghua Industry Park,Zhonghua Road,Minzhi,Baoan District,Shenzhen,Guangdong,China
- Country/Region : China
Mean Well Power Supply, NES-25-12
Original Mean Well Power Supply, NES-25-12,85~264V AC universal input, output:12V DC,0~2.1A, 25.2W
NES-15-12
1. Output:
1) DC Voltage: DC12V
2) Rated currrent: 2.1A
3) Current range: 0~2.1A
4) Raged power: 25.2W
5) RIPPLE & NOISE (max.) Note.2: 120mVp-p
6) VOLTAGE ADJ. RANGE: 10.8 ~ 13.2V
7) VOLTAGE TOLERANCE Note.3: ±1%
8) VOLTAGE TOLERANCE Note.3: ±0.5%
9) LOAD REGULATION Note.5: ±0.5%
10) SETUP, RISE TIME:500ms, 30ms/230VAC
11) HOLD UP TIME (Typ.):50ms/230VAC
2. Input:
1) VOLTAGE RANGE:85 ~ 264VAC
2) FREQUENCY RANGE:47 ~ 63Hz
3) EFFICIENCY (Typ.):83%
4) AC CURRENT (Typ.): 0.35A/230VAC
5) INRUSH CURRENT (Typ.): COLD START 45A
6) LEAKAGE CURRENT: <2mA / 240VAC
3. Protection:
1) OVERLOAD 110~150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
2) OVER VOLTAGE:13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover.
4. SAFETY & EMC (Note 6)
1) SAFETY STANDARDS: UL60950-1, CB(IEC60950-1),CCC GB4943 approved
2) WITHSTAND VOLTAGE:I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
3) ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 °C/ 70% RH
4) EMC EMISSION: Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
5) EMC IMMUNITY:Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A
5. Others
1) 411.47Khrs min. MIL-HDBK-217F (25°C)
2) DIMENSION: 99*82*35mm(L*W*H)
3) 0.3Kg; 45pcs/14.5Kg/0.66CUFT
6. Notes:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4. Line regulation is measured from low line to high line at rated load.5. Load regulation is measured from 0% to 100% rated load.6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
Mean Well Power Supply, NES-25-12